QSI 500 SERIES USER GUIDE
Launch MaxIm LE. Choose “Set Calibration” from the Process menu. That will open the
Set Calibration window.
By default, MaxIm expects to calibrate images with bias frames, dark frames and flat fields.
For this example we’re only going to show calibrating with bias frames and dark frames.
Note: MaxIm also has a Calibration Wizard that steps you through the process of
setting up your image calibration. For details on the Calibration Wizard please
consult the online help in MaxIm LE.
If you’re not calibrating with flats, as in this example, uncheck the three “Flat” checkboxes
along the top of the Set Calibration window.
53